<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Євген, автор у Polymetrica</title>
	<atom:link href="https://new.polymetrica.com/en/author/dsigner/feed/" rel="self" type="application/rss+xml" />
	<link>https://new.polymetrica.com/en/author/dsigner/</link>
	<description>Промисловий IoT</description>
	<lastBuildDate>Tue, 22 Sep 2026 09:59:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://new.polymetrica.com/wp-content/uploads/2025/12/logo_polymetrica_sq-100x100.png</url>
	<title>Євген, автор у Polymetrica</title>
	<link>https://new.polymetrica.com/en/author/dsigner/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Our Latest Development! PDU-IRL!</title>
		<link>https://new.polymetrica.com/en/our-latest-development-pdu-irl/</link>
		
		<dc:creator><![CDATA[Євген]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 09:58:55 +0000</pubDate>
				<category><![CDATA[Без категорії]]></category>
		<category><![CDATA[Our development]]></category>
		<guid isPermaLink="false">https://new.polymetrica.com/?p=18249</guid>

					<description><![CDATA[<p>Introducing a wireless LoRaWAN controller designed for intelligent and energy-efficient management of air conditioners and split systems via an infrared (IR) channel. The device fully...</p>
<p>Запис <a href="https://new.polymetrica.com/en/our-latest-development-pdu-irl/">Our Latest Development! PDU-IRL!</a> спершу з'явиться на <a href="https://new.polymetrica.com/en/home-en/">Polymetrica</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex">
<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="768" height="1024" src="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-768x1024.jpg" alt="" class="wp-image-18250" srcset="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-768x1024.jpg 768w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-225x300.jpg 225w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-600x800.jpg 600w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-1x1.jpg 1w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3-8x10.jpg 8w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4660-3-3.jpg 1152w" sizes="(max-width: 768px) 100vw, 768px" /></figure>



<figure class="wp-block-image size-large"><img decoding="async" width="768" height="1024" src="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-768x1024.jpg" alt="" class="wp-image-18253" srcset="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-768x1024.jpg 768w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-225x300.jpg 225w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-600x800.jpg 600w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-1x1.jpg 1w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1-8x10.jpg 8w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4663-3-1.jpg 1152w" sizes="(max-width: 768px) 100vw, 768px" /></figure>
</div>



<div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex">
<figure class="wp-block-image size-large"><img decoding="async" width="768" height="1024" src="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-768x1024.jpg" alt="" class="wp-image-18252" srcset="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-768x1024.jpg 768w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-225x300.jpg 225w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-600x800.jpg 600w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-1x1.jpg 1w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1-8x10.jpg 8w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4662-3-1.jpg 1152w" sizes="(max-width: 768px) 100vw, 768px" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="768" height="1024" src="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-768x1024.jpg" alt="" class="wp-image-18251" srcset="https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-768x1024.jpg 768w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-225x300.jpg 225w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-600x800.jpg 600w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-1x1.jpg 1w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1-8x10.jpg 8w, https://new.polymetrica.com/wp-content/uploads/2026/09/IMG_4661-1.jpg 1152w" sizes="(max-width: 768px) 100vw, 768px" /></figure>
</div>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph">Introducing a wireless LoRaWAN controller designed for intelligent and energy-efficient management of air conditioners and split systems via an infrared (IR) channel.</p>



<p class="wp-block-paragraph">The device fully emulates the operation of an original remote control, allowing seamless integration of any residential, commercial, or industrial air conditioner into a unified Smart Home, BMS (Building Management System), or IoT dispatching platform.</p>



<p class="wp-block-paragraph"><strong>KEY FEATURES AND ADVANTAGES<br></strong>• Autonomy and Power Flexibility:<br>Autonomous operation mode powered by an internal battery for 3–5 years (thanks to deep power consumption optimization).<br>Option to connect a 12V DC stationary power supply for installations requiring continuous connectivity and frequent data transmission.</p>



<p class="wp-block-paragraph">• LoRaWAN Technology:<br>Built on top of the energy-efficient RAKWireless (RAK3172) module.<br>Provides long-range coverage (up to several kilometers) and strong signal penetration in reinforced concrete structures.</p>



<p class="wp-block-paragraph">• Complete IR Control Cycle:<br>IRT (Infrared Transmitter) — Controls the air conditioner (power ON/OFF, mode selection, temperature setpoint adjustment, fan speed).<br>IRR (Infrared Receiver) — Reads and learns commands directly from the original remote control for quick setup with any brand.</p>



<p class="wp-block-paragraph">• Precise Temperature Control:<br>Dedicated interface for connecting an external DS18B20 digital temperature sensor (connected via terminal blocks).<br>Allows reading real-time temperature at the air outlet or directly within the working area of the room.</p>



<p class="wp-block-paragraph"><strong>TECHNICAL SPECIFICATIONS<br></strong>• Communication Protocol: LoRaWAN<br>• Wireless Module: RAK3172 (RAKwireless)<br>• Control Interfaces: IR Transmitter (IRT), IR Receiver (IRR)<br>• Sensor Interfaces: DS18B20 (1-Wire)<br>• Power Supply Voltage: 12V DC or Autonomous Battery (3–5 years)<br>• Enclosure Design: Protective plastic case with an external SMA antenna connector and convenient screw terminal blocks.</p>



<p class="wp-block-paragraph"><strong>TARGET APPLICATIONS<br></strong>• Commercial &amp; Office Real Estate:<br>Automatic shutdown or switching air conditioners to eco-mode after working hours or on weekends.</p>



<p class="wp-block-paragraph">• Hotels, Apartments &amp; HoReCa:<br>Centralized climate control and turning off air conditioning when guests are away from the room.</p>



<p class="wp-block-paragraph">• Server Rooms, Base Stations &amp; Telecom Infrastructure:<br>Temperature monitoring and emergency cooling activation or redundancy if temperature thresholds are exceeded.</p>



<p class="wp-block-paragraph">• Energy Management &amp; Dispatching:<br>Reducing electricity costs by optimizing climate equipment operation schedules.</p>



<p class="wp-block-paragraph"></p>
<p>Запис <a href="https://new.polymetrica.com/en/our-latest-development-pdu-irl/">Our Latest Development! PDU-IRL!</a> спершу з'явиться на <a href="https://new.polymetrica.com/en/home-en/">Polymetrica</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
